Поиск...
UUAVSale

SNC200A-IMU MEMS Inertial Measurement Unit

SKU: MD-P00342·Spare Parts & Components·Под заказ

SNC200A-IMU MEMS Inertial Measurement Unit
SNC200A-IMU MEMS Inertial Measurement Unit

Обзор

SNC200A-IMU MEMS Inertial Measurement Unit is an inertial measurement unit (IMU) based on MEMS technology. It has built-in high-performance MEMS gyroscope and MEMS accelerometer, and outputs 3 angular velocities and 3 accelerations. SNC200A-IMU MEMS Inertial Measurement Unit has high reliability and strong environmental adaptability. By matching different software, the products can be widely used in intelligent driving, tactical and industrial UAVs, intelligent ammunition, seeker, communication in motion, surveying and mapping, stable platform and other fields. 1. Main application fields ▶ Tactical and industrial UAV ▶ Seeker, photoelectric pod ▶ Unmanned ship, unmanned vehicle ▶ High precision ten axis IMU ▶ Large range gyro (2000 / s) can be configured ▶ Suitable for strong vibration environment ▶ It has high reliability and is widely used in target aircraft, Tactical UAV and missile 3. Physical dimensions, electrical characteristics and system performance indicators 3.1 System performance index 3.2 Physical dimensions and electrical characteristics Power consumption: < 1.5W 3.3 Environmental indicators Operating temperature: - 40 ℃ ~ + 60 C Storage temperature: - 45 ℃ ~ + 75 ℃ Vibration: 20 ~ 2000Hz, 6.06g Continuous working time: > 120h 3.4 Interface characteristics One SPI: sampling frequency within 1000Hz can be configured

Технические характеристики

Specifications. Основные характеристики: Parameter Test conditions / index, Gyro Dynamic measurement range / 450-2000 / S (optional), Zero bias stability 10s average (- 40 ℃ ~ + 70 ℃) / 3 /h, Zero bias Zero bias range / 0.03 /s, Zero bias change in full temperature range Soil 0.02 / s, Start repeatability 0.003 /s, Influence of vibration on zero bias 0.002 /s/g, Scale factor nonlinearity 0.01%FS, Resolving power three point zero five two 10-7 /s/LSB, Bandwidth 200Hz, Accelerometer Dynamic measurement range / 16g-200g available, 10s average zero bias stability (- 40 ℃ ~ + 70 ℃, constant temperature) 0.2mg, Full temperature zero bias change 5mg, Magnetometer Dynamic measurement range / 2.5 gauss, sensitivity 0.1 mgauss/LSB, Nonlinearity 0.5%FS, Barometer Pressure range / 450~1100 mbar, Total error 4.5 mbar, relative error 2.5 mbar, Voltage 3.3V, Power consumption < 1.5W, Size 47mmx44mmx14mm, Weight < 50g, Operating temperature - 40 ℃ ~ + 60 C, Storage temperature - 45 ℃ ~ + 75 ℃, Vibration 20 ~ 2000Hz, 6.06g, Impact 1000g, 0.5mg, MTBF >20000h, Continuous working time > 120h, One SPI sampling frequency within 1000Hz can be configured, 1-way UART 200Hz, 1 channel can 200Hz.

Технические характеристики — 1 groups
Основные характеристики: Parameter Test conditions / index, Gyro Dynamic measurement range / 450-2000 / S (optional), Zero bias stability 10s average (- 40 ℃ ~ + 70 ℃) / 3 /h, Zero bias Zero bias range / 0.03 /s, Zero bias change in full temperature range Soil 0.02 / s, Start repeatability 0.003 /s, Influence of vibration on zero bias 0.002 /s/g, Scale factor nonlinearity 0.01%FS, Resolving power three point zero five two 10-7 /s/LSB, Bandwidth 200Hz, Accelerometer Dynamic measurement range / 16g-200g available, 10s average zero bias stability (- 40 ℃ ~ + 70 ℃, constant temperature) 0.2mg, Full temperature zero bias change 5mg, Magnetometer Dynamic measurement range / 2.5 gauss, sensitivity 0.1 mgauss/LSB, Nonlinearity 0.5%FS, Barometer Pressure range / 450~1100 mbar, Total error 4.5 mbar, relative error 2.5 mbar, Voltage 3.3V, Power consumption < 1.5W, Size 47mmx44mmx14mm, Weight < 50g, Operating temperature - 40 ℃ ~ + 60 C, Storage temperature - 45 ℃ ~ + 75 ℃, Vibration 20 ~ 2000Hz, 6.06g, Impact 1000g, 0.5mg, MTBF >20000h, Continuous working time > 120h, One SPI sampling frequency within 1000Hz can be configured, 1-way UART 200Hz, 1 channel can 200Hz.

Технические характеристики

Specifications

Parameter
Test conditions / index
Gyro
Dynamic measurement range / 450-2000 / S (optional)
Zero bias stability
10s average (- 40 ℃ ~ + 70 ℃) / 3 /h
Zero bias
Zero bias range / 0.03 /s
Zero bias change in full temperature range
Soil 0.02 / s
Start repeatability
0.003 /s
Influence of vibration on zero bias
0.002 /s/g
Scale factor nonlinearity
0.01%FS
Resolving power
three point zero five two 10-7 /s/LSB
Bandwidth
200Hz
Accelerometer
Dynamic measurement range / 16g-200g available
10s average zero bias stability (- 40 ℃ ~ + 70 ℃, constant temperature)
0.2mg
Full temperature zero bias change
5mg
Magnetometer
Dynamic measurement range / 2.5 gauss
sensitivity
0.1 mgauss/LSB
Nonlinearity
0.5%FS
Barometer
Pressure range / 450~1100 mbar
Total error
4.5 mbar
relative error
2.5 mbar
Voltage
3.3V
Power consumption
< 1.5W
Size
47mmx44mmx14mm
Weight
< 50g
Operating temperature
- 40 ℃ ~ + 60 C
Storage temperature
- 45 ℃ ~ + 75 ℃
Vibration
20 ~ 2000Hz, 6.06g
Impact
1000g, 0.5mg
MTBF
>20000h
Continuous working time
> 120h
One SPI
sampling frequency within 1000Hz can be configured
1-way UART
200Hz
1 channel can
200Hz

Совместимые летательные аппараты

Эта деталь подходит к следующим платформам.

Данные о совместимости уточняются — свяжитесь с нами и укажите модель аппарата.

Документы